That still FAILS the fiberstress in bending test. Using three columns across the length reduces the span for each to approximately 120" (10 ft) The calculator tells me that 4 layers of 2x12 (actual beam width of 6" and depth of 11.25" will FAIL the Fiberstress in bending test and the deflection test. (the calc is fixed to use a value of L/360 on floors)īut let's see what happens when we use. Using Don_P's simple beam calculator and the following data for SYP. Half of that will rest on the center beam and a quarter on each side wall.Ģ4750 / 2 = 12375 on the center beam for each segment. If we call the LL to be 40 PSF, let's call the DL out at 15 PSF. Let's call that a 32 x 42 building that = 1344 sq ft.ĭivide that into three parts = 448 sq ft per section I always though it was better to stagger the joints to minimize a hinge effect over the column, but he says his way is correct. My contractor (NOT an engineer) says a beam built up out of 3 or 4 2X12's will be 'plenty', but of course, the inspector has to believe that, too.Īs an aside, my contractor builds such beams with all of the joints over the column. Materials available locally are #2 southern yellow pine- strong stuff. Design load should be 40 psf minimum live load, and I want a L/480 stiffness. I don't have enough room to put them on top of the carrier beam, so they will be attached with hangers. They will be hung from ledgers at the edges, and the carrier beam in the middle. Specs- The floor joists will be 2X12's on 16" centers. The lumber yard said I would need an LVL, but what did they do before those were around? I show two evenly spaced support posts, but could go with three if it would help. I'm attaching a drawing with the dimensions. The only time you would ever need to use bolts would be if the material had such severe deformities such as a bad “cup” which could not be overcome by nails.I'm wondering if there's a way to prescriptively calculate the carrier beam I need for my main floor. We have learned from our experience to use at least a 3 1/4″‘x.131″ groove shank nail in a column of four every foot apart down the laminate. staggered pattern with at least a 3″x.120″ nail. The 2012 IRC code calls for a minimum of a 32″ O.C. Fasteningīeams of more than one ply must be fastened together with either nails or bolts. On longer spans the beam may require much more bearing space as indicated by this table. Anything 5′ and above we always at least double cripple. BearingĪccording to the 2012 IRC codes any beam, joist, or header shall never have a bearing of less than 1 1/2″. These small areas are usually door opening on the interior and people are trained that these areas are the strongest place in a house to be in the case of an emergency. It has been my experience to never use a beam smaller than a two ply 2 x 8. This calculator matches up with 90% of the applications in the 2012 International Residential Code book. If there is are any questions about anything else, then you should contact your supplier or an engineer. Most interior beams need to include the roof load. You only have to select all of the loads that apply. This calculator takes all of this into consideration. This will amount to twice as much load on the exterior walls compared to a building with a center wall. For example, if building is 24′ x 24′ and has trusses, and the load on the roof will be for 30 lb snow load and a ceiling with no storage will total out like this. The load on an outside wall with clear span trusses is exactly half the load on each wall. In other words, it is either going to be on an outside wall, or somewhere on the inside. Its either going to an exterior or an interior load.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |